semplr.

Exams · Certifications · Licensing

Asbestos accreditation exam (AHERA/MAP Inspector and Abatement Worker)

Respiratory protection and PPE: practice questions

Our Asbestos Inspector / Worker bank has 22 questions on this topic. Here are 5 of them with answers; the full mock exam draws from every topic, like the real one.

Start the free mock exam

Question 1

Why does facial hair matter for tight-fitting respirators?

  1. It makes the mask warmer but does not affect fit
  2. It has no effect on respirator protection at all
  3. It filters fibers out of the air like a HEPA filter
  4. It can break the seal between the face and facepiece
Show the answer

D. It can break the seal between the face and facepiece — 1910.134(g)(1)(i)(A) prohibits facial hair between the sealing surface and the face or interfering with valves.

Question 2

A worker tears a suit while working in the regulated area. What does OSHA require?

  1. Cover it with duct tape tomorrow
  2. Finish the shift, then replace it
  3. Report it at the weekly meeting
  4. Mend it or replace it immediately
Show the answer

D. Mend it or replace it immediately — 1926.1101(i)(4)(ii) requires rips and tears to be mended or the suit replaced immediately.

Question 3

Grade D breathing air must have an oxygen content of:

  1. At least 25 percent
  2. 16 to 19.5 percent
  3. 21 to 30 percent
  4. 19.5 to 23.5 percent
Show the answer

D. 19.5 to 23.5 percent — 1910.134(i)(1)(ii)(A) specifies oxygen content of 19.5-23.5%.

Question 4

An oxygen-deficient atmosphere under 1910.134 has oxygen below:

  1. 19.5 percent
  2. 23.5 percent
  3. 16 percent
  4. 21 percent
Show the answer

A. 19.5 percent — 1910.134(b) defines oxygen deficient as below 19.5% by volume.

Question 5

How often must a tight-fitting respirator be fit-tested under 29 CFR 1910.134?

  1. Only once, when the worker is first hired
  2. Before first use and at least annually
  3. Every 3 years, or when the worker asks
  4. Every 5 years, at each refresher course
Show the answer

B. Before first use and at least annually — 1910.134(f)(2) requires fit testing before initial use, when the facepiece changes, and at least annually.

More Asbestos Inspector / Worker topics