Question 1
What fire extinguisher coverage does OSHA require in a building under construction?
- One 10B extinguisher on each floor, placed wherever it is most convenient for crews
- One extinguisher at the main gate
- One 2A extinguisher per 3,000 sq ft, within 100 feet of travel
- One extinguisher per 10,000 sq ft
Show the answer
C. One 2A extinguisher per 3,000 sq ft, within 100 feet of travel — OSHA 1926.150(c)(1).
Question 2
How often must a competent person inspect scaffolds for visible defects?
- Before each work shift and after anything that could affect integrity
- Only when the scaffold is first erected
- Once a week, with a written log kept in the site office for review by OSHA
- Once a month
Show the answer
A. Before each work shift and after anything that could affect integrity — OSHA 1926.451(f)(3).
Question 3
Above what height must workers on a scaffold be protected from falls?
- More than 20 feet above a lower level
- More than 6 feet, the same as other surfaces
- More than 15 feet above a lower level
- More than 10 feet above a lower level
Show the answer
D. More than 10 feet above a lower level — OSHA 1926.451(g)(1).
Question 4
Under the hazard communication standard, what must be available for each hazardous chemical on site?
- A building permit
- A safety data sheet (SDS)
- A purchase receipt
- A warranty card
Show the answer
B. A safety data sheet (SDS) — Containers must also be labeled and workers trained (1926.59 / 1910.1200).
Question 5
What is the minimum strength of an anchorage used for personal fall arrest, if not designed by a qualified person?
- 500 pounds per employee
- 1,000 pounds per employee attached, with a safety factor of two
- 2,000 pounds for every two employees attached
- 5,000 pounds per employee attached
Show the answer
D. 5,000 pounds per employee attached — Or designed with a safety factor of at least two under a qualified person's supervision (1926.502(d)(15)).
More NASCLA Commercial GC topics
- Site construction: excavation
- Site construction: stormwater
- Site construction: earthwork
- Concrete
- Masonry
- Metals
- Wood
- Doors, windows and glazing
- Mechanical and plumbing
- Electrical
- Procurement and contracting: payroll taxes
- Procurement and contracting: contracts
- Procurement and contracting: insurance
- Procurement and contracting: business organization
- Procurement and contracting: project administration