semplr.

Exams · Certifications · Licensing

EPA Lead Renovation, Repair and Painting (RRP) Certified Renovator course test

Testing for lead-based paint: practice questions

Our EPA Lead RRP Renovator bank has 18 questions on this topic. Here are 5 of them with answers; the full mock exam draws from every topic, like the real one.

Start the free mock exam

Question 1

What is the regulated lead level that a recognized test kit is designed to detect?

  1. Any detectable lead
  2. 1.0 mg/cm² or more than 0.5% by weight
  3. 5 mg/cm² or 1% by weight
  4. 0.1 mg/cm² or 0.06% by weight
Show the answer

B. 1.0 mg/cm² or more than 0.5% by weight — Section 745.83 defines a recognized test kit as able to detect lead at or above 1.0 mg/cm² or more than 0.5% by weight.

Question 2

Under 745.88, which EPA program tests kits for recognition?

  1. The Toxics Release Inventory reporting program
  2. EPA's Environmental Technology Verification Program
  3. The Energy Star product labelling program
  4. The WaterSense fixture labelling program
Show the answer

B. EPA's Environmental Technology Verification Program — Section 745.88(b) says kits are tested through EPA's Environmental Technology Verification Program or an equivalent approved program.

Question 3

Test kit results showing no lead-based paint on the affected components mean the firm:

  1. Need not follow RRP work practices for those components
  2. Must still deliver the pamphlet for those components
  3. Must still use full containment for those components
  4. Must notify EPA in writing before starting the work
Show the answer

A. Need not follow RRP work practices for those components — Section 745.82(a)(2) makes the subpart inapplicable when every affected component is tested and found free of lead-based paint.

Question 4

Who may use an EPA-recognized test kit to qualify a job for the test-kit exemption?

  1. Any homeowner
  2. Any worker trained on the job
  3. A certified renovator
  4. A real estate agent
Show the answer

C. A certified renovator — Section 745.82(a)(2) requires a certified renovator using a recognized kit and following the manufacturer's instructions.

Question 5

Paint chip samples must be analysed by which kind of laboratory?

  1. An EPA-recognized (NLLAP) laboratory
  2. A state drinking water laboratory
  3. The renovator's own field laboratory
  4. Any hospital laboratory that tests blood lead
Show the answer

A. An EPA-recognized (NLLAP) laboratory — Section 745.82(a)(3) requires analysis by an EPA-recognized laboratory under TSCA 405(b); records name the NLLAP-recognized entity.

More EPA Lead RRP Renovator topics