Question 1 · Wastewater Treatment Class I

Which device measures open-channel flow using a constriction?

  1. Turbidimeter
  2. Pressure gauge
  3. Parshall flume
  4. Magnetic flowmeter
Show the answer

C. Parshall flume — Level upstream of the throat gives the flow.

Question 2 · Wastewater Treatment Class I

Why is telemetry used at remote lift stations?

  1. To clean pumps
  2. To send alarms and status to operators so problems are caught quickly
  3. To bill customers and measure BOD
  4. To measure BOD
Show the answer

B. To send alarms and status to operators so problems are caught quickly — SCADA and telemetry are listed.

Question 3 · Wastewater Treatment Class I

What does an ORP (oxidation-reduction potential) probe help monitor?

  1. Turbidity
  2. Grit level
  3. Whether conditions are aerobic, anoxic or anaerobic, and chlorine/dechlorination
  4. Flow rate and sludge depth
Show the answer

C. Whether conditions are aerobic, anoxic or anaerobic, and chlorine/dechlorination — Measured in millivolts.